Document toolboxDocument toolbox

av.mcafee

Introduction

The tags beginning with av.mcafee identify events generated by McAfee ePO.

There are several methods of ingestion from McAfee ePO. Using the Devo relay is the first method. The second method is using the third-party tool Logstash.

Valid tags and data tables

The full tag must have 4 levels. The first two are fixed as av.mcafee The third level identifies the type of events sent, and the fourth level indicates the event subtype. 

Technology

Brand

Type

Subtype

av

mcafee

epo


  • agent
  • endpointsecurity
  • virusscan

These are the valid tags and corresponding data tables that will receive the parsers' data:

Tag

Data table

av.mcafee.epo.agent

av.mcafee.epo.agent

av.mcafee.epo.endpointsecurity

av.mcafee.epo.endpointsecurity 

av.mcafee.epo.virusscan

av.mcafee.epo.virusscan

How is data sent to Devo?

McAfee ePO can be configured to synchronize with a Syslog server. You can take advantage of this to send the data to a Devo Relay and then forward it to Devo. According to McAfee documentation, their Syslog forwarding only supports TCP over TLS, so you would need to install Stunnel in your Devo Relay machine, create your certificates and configure Stunnel.

The Stunnel configuration must include the incoming port where the McAfee ePO will send the logs to the Stunnel, the outgoing port where the Stunnel will forward the decrypted logs to the Devo Relay, and the necessary certificates. For more information about Stunnel, you can check this Devo’s documentation page and the official Stunnel website.

Devo Relay rules

Logs generated by McAfee ePO must be sent to the Devo platform via the Devo Relay to secure communication. When your Devo Relay is receiving Syslog messages, through port 13006, the Relay will be able to forward these logs to the right Devo tables.See the required relay rules below:

Relay rule 1 - McAfee ePO

  • Source port 13006

  • Source data → ProductName=\"McAfee Agent\"

  • Target tag → av.mcafee.epo.agent

  • Select the Stop processing and Sent without syslog tag checkboxes

Relay rule 2 - McAfee Endpoint Security

  • Source Port  13006

  • Source Data → ProductName=\"McAfee Endpoint Security\"

  • Target Tag → av.mcafee.epo.endpointsecurity

  • Select the Stop Processing and Sent without syslog tag checkboxes

Relay rule 3 - McAfee VirusScan

  • Source Port  13006

  • Source Data → ProductName=\"VirusScan Enterprise\"

  • Target Tag → av.mcafee.epo.virusscan

  • Select the Stop Processing and Sent without syslog tag checkboxes

Relay rule 4 - McAfee others

Use this rule you want to send to a my.app table all logs that do not match the previous rules.

  • Source Port  13006

  • Source Data → 

  • Target Tag → my.app.mcafee.epo

  • Select the Stop Processing and Sent without syslog tag checkboxes

Logstash method

Events generated by McAfee EPO Console are stored in its SQL database in a table named EPOEventsMT or EPOEvents. We can use Logstash to extract the events from the database using JDBC, apply the av.mcafee.epo.events tag to each event, then send them in syslog format to port 13000 on the Devo Relay. 

Because Logstash saves the ID of the last record read in a dedicated file, each time the query is run only new records are retrieved and sent to Devo.

Prerequisites

  • Logstash requires a database user with read permissions on the EPO tables.
  • Some database fields need to be converted from signed int to a varchar IP address. The following function can do this for you.

    CREATE FUNCTION [dbo].[IntegerToIPAddress] (@ipin int)
    RETURNS CHAR(15)
    AS
    BEGIN
    declare @o1 bigint, @o2 bigint, @o3 bigint, @o4 bigint;
    declare @ip bigint;
    -- This is the magic epo conversion size...
    set @ip = (CAST(@ipin as bigint) + 2147483647) + 1;
    SET @o1 = @ip / 16777216;
    SET @ip = @ip % 16777216;
    SET @o2 = @ip / 65536;
    SET @ip = @ip % 65536;
    SET @o3 = @ip / 256;
    SET @ip = @ip % 256;
    SET @o4 = @ip;
    RETURN
    CONVERT(VARCHAR(4), @o1) + '.' +
    CONVERT(VARCHAR(4), @o2) + '.' +
    CONVERT(VARCHAR(4), @o3) + '.' +
    CONVERT(VARCHAR(4), @o4)
    END
  • Install Logstash on the same machine as the Devo Relay and download the logstash-output-syslog plugin.

  • Download and decompress the Microsoft JDBC Driver 4.1 for SQL Server into the /var/lib/logstash directory on the Devo Relay machine.

Configure Logstash

Create the configuration file that will direct the extraction and sending of events in /etc/logstash/conf.d. For example, /etc/logstash/conf.d/epo-DevoRelay.conf.

The following configuration file is a model which will extract new events from the database using the JDBC driver every one minute and send them using the syslog plugin to port 13000 on the Devo Relay. The parameters enclosed in angled brackets (<>) should be modified for your environment.

input {
	jdbc {
        jdbc_driver_library => "/var/lib/logstash/sqljdbc_4.1/enu/sqljdbc41.jar"
        jdbc_driver_class => "com.microsoft.sqlserver.jdbc.SQLServerDriver"
        jdbc_connection_string => "jdbc:sqlserver://<ip_epo_server>\EPOSERVER:<port>;databaseName=<db_instance_name>"
        jdbc_user => "<username>"
        jdbc_password => "<password>"
        schedule => "* * * * *"   #each 1 minute
        use_column_value => true
        tracking_column => "autoid"
        last_run_metadata_path => "/var/lib/logstash/.logstash_jdbc_last_run"
        statement => "select autoid,AutoGUID,ServerID,CONVERT(varchar(24),DetectedUTC,120) as detectedUTC,dbo.IntegerToIPAddress(SourceIPV4) as SourceIP,dbo.IntegerToIPAddress(TargetIPV4) as TargetIP,TargetUserName,TargetFileName,SourceHostName,TargetHostName,ThreatCategory,ThreatEventID,ThreatSeverity,ThreatName,ThreatActionTaken,ThreatHandled from dbo.EPOEventsMT where autoid > :sql_last_value"
    }
}
# filter {
#
# }

output {
	syslog {
        facility => "local7"
        severity => "informational"
    	host => "localhost"
    	port => 13000 
        sourcehost => "<epo_server_name>"
    	appname => "av.mcafee.epo.events"
        protocol => "tcp"
        codec => line {
            format => "mcafeeEPO,%{autoid},%{autoguid},%{serverid},%{detectedutc},%{sourceip},%{targetip},%{targetusername},%{targetfilename},%{sourcehostname},%{targethostname},%{threatcategory},%{threateventid},%{threatseverity},%{threatname},%{threatactiontaken},%{threathandled}"
        }
	}
}
  • Add the Logstash service to be started at bootup using this command:

    update-rc.d - f logstash defaults 50
  • Finally, start the Logstash service:

    /etc/init.d/logstash start
    

Now you can confirm that the events are being correctly extracted and sent to Devo.

  • Log into the Devo web application and domain to which you are sending the EPO events.
  • Open the Finder in the Data Search area and locate the av.mcafee.epo.events table.