Tags beginning with edr.cylance identify log events generated by Cylance PROTECT endpoint protection.

Tag structure

The full tag has only three levels. The first two are fixed as edr and cylance. The third level of the tag identifies the supported Cylance log event type.

technology

brand

type

subtype

edrcylance
  • app
  • audit
  • device
  • memory
  • script
  • threats
Not used

Therefore, the valid tags include:

  • edr.cylance.app
  • edr.cylance.audit
  • edr.cylance.device
  • edr.cylance.memory
  • edr.cylance.script
  • edr.cylance.threats

All events sent with these tags are saved in tables with the same name. In addition, a parent table called simply edr.cylance will be created automatically and contains all events that were received with a tag beginning with edr.cylance.

For more information, read more about Devo tags.

Configuration

In Cylance you need to set up a Syslog/SIEM integration in order to forward events to your Devo Relay.

On the relay, you need to define a series of rules that identify the event types by a string found in the source message, then apply the corresponding tag. To prevent further rule processing on events that match a rule, we make sure to select the Stop processing checkbox.

In the examples below, we use port 13003 but you should use any port that you can dedicate to these events. And this port should be the one you set up Cylance to send the events to.

Rule 1: AppControl events

  • Source Port → 13003
  • Source Message → Event Type: AppControl
  • Target Tag → edr.cylance.app
  • Check the Stop processing checkbox.

Rule 2: AuditLog events

  • Source Port → 13003
  • Source Message → Event Type: AuditLog
  • Target Tag → edr.cylance.audit
  • Check the Stop processing checkbox.

Rule 3: Device management events

  • Source Port → 13003
  • Source Message → Event Type: Device
  • Target Tag → edr.cylance.device
  • Check the Stop processing checkbox.

Rule 4: Memory protection events

  • Source Port → 13003
  • Source Message → Event Type: ExploitAttempt
  • Target Tag → edr.cylance.memory
  • Check the Stop processing checkbox.

Rule 5: Script Execution control events

  • Source Port → 13003
  • Source Message → Event Type: ScriptControl
  • Target Tag → edr.cylance.script
  • Check the Stop processing checkbox.

Rule 6: Threat and threat classification events

  • Source Port → 13003
  • Source Message → Event Type: Threat
  • Target Tag → edr.cylance.threat
  • Check the Stop processing checkbox.